Section 8Component Replacement Procedures
8-12
DOOR INSTALLATION
WARNING
To prevent personal injury and/or cabinet
damage, perform this procedure with two
people, each capable of lifting 75 lb. (34 kg).
1. Be sure the top and bottom hinge brackets
are securely mounted to the cabinet.
2. Be sure the top hinge pin and the
torquemaster are properly mounted to the
hinge brackets.
3. Use a standard screwdriver to carefully
pry the outer shaft retainer from the
torquemaster.
4. Slide the door up into the top hinge pin
bracket.
5. Align and engage the hold-open arm stud
on the door with the key hole on the hold-
open arm. Do not lower the door yet, or
you will bend the hold-open arm.
6. Lift up on the door and slide it into the
torquemaster on the bottom hinge bracket.
7. Install the safety snap ring on the top pin
shaft.
8. Install the outer shaft retainer on the
torquemaster.
9. Adjust the door as necessary. See Tension
Adjustment and/or Door Sag Adjustment,
both on page 8-11.
Figure 8-14: Bottom Hinge Bracket Assembly
Temperature/Humidity Chart for
Condensation On Glass Doors
Glass door refrigerators use two-pane
reflective, non-heated glass (NHG).
Condensation will form on the glass if the unit
is installed in a high humidity area.
Atmospheric conditions vary depending on
specific operating conditions. Use the chart
below as a guideline when selecting an
installation space.
Room Temperature Relative Humidity
70°F/21.1°C 76%
75°F/23.9°C 72%
80°F/26.7°C 69%
85°F/29.4°C 67%
90°F/32.2°C 65%
*Based on interior cabinet temperature of 38°F/3.3°C.
SV1503
BOTTOM HINGE
BRACKET
KEYHOLE
HOLD OPEN
ARM
DOOR SAG
ADJUSTMENT
DOOR TRAVEL (TENSION) ADJUSTMENT
TORQUEMASTER
TORQUEMASTER MOUNTING SCREW
SHAFT RETAINER